47 Overdentures

 

Please refer to following chairside guides to aid in overdenture appointment. Please review with faculty the steps prior to each patient case.

Below is brief outline for overdenture pick-up impression process. Please review straumann guide for detailed photos and step by step instructions.

  1. Locator Abutment Selection & Placement
    • Select correct abutment height based on gingival tissue thickness
      • The length from implant platform to gingiva at highest point = cuff height of locator abutment
    • Torque abutment per manufacturer guidelines (usually 20–30 Ncm)
  2. Block-Out for Pick-Up
    • Place block-out spacers around the abutment (White O-Rings)
    • Use rubber dam or soft wax to protect undercuts and prevent acrylic locking in place
  3. Chairside Pick-Up Process
    • Adjust denture to relieve space for housing
      • Fit checker or PIP can help locate where to relieve denture
    • Roughen fitting surface and clean thoroughly
    • Inject auto-polymerizing acrylic into prepared space
    • Seat denture passively and hold during polymerization (about 5-7 minutes)
    • Remove excess material and polish
    • Metal housing is now retained in denture
  4. Retentive Element Placement
    • Use locator core tool to remove black insert and place appropriate nylon insert (retention strength based on color code)
      • Start with light and at recall can determine if increased is neeed
      • Blue = 1.5lbs, Pink = 3lbs, Blue = 5 lbs
      • Extended range available for non-parallel/non-ideal implant placements as needed
    • Ensure insert is fully seated into metal housing

5. Verify Prosthesis Stability

    • Check for rocking or instability
    • Ensure bilateral seating and retention
    • Confirm patient can seat and remove the prosthesis independently

6. Patient Education

      • Teach insertion/removal technique using index fingers and thumbs
      • Provide hygiene instructions:
        • Clean overdenture and around abutments daily
        • Use denture brush and non-abrasive cleanser
        • Recommend water flosser or soft-tipped proxy brush around abutments
      • Discuss follow-up schedule and wear expectations

7. Documentation

  • Add prosthetic portion of the “Implant Documentation Form”
  • Note + Code approved and reviewed with faculty
  • Include materials, torque, materials, and other relevant information
  • Add 1- year recall code

 

8. Recall Visit (D0120)

  • Intra-oral/extra oral exam
  • Periodontal probing
  • Percussion
  • Evaluate denture (Stability, wear, retention, occlusion)
  • PA radiographs of implants
  • Replacement of retentive inserts as needed

 